摘要

概述了2种步态分析实验系统、实验原理和KOA患者下肢三维步态的改变;由于下肢生物力学的复杂性和研究技术的局限性,3D矫形鞋垫设计目前仍处于初级阶段,产品的治疗效果尚无统一意见并且未大量生产使用,因此对3D矫形鞋垫在KOA中的应用原理及制作过程进行深入探讨,明确KOA患者膝关节周围动力和静力结构变化,将其应用于3D矫形鞋垫的设计和生产,为早期KOA保守治疗提供重要解决方案,既能够患者满足舒适性和功能性的双重需求,又能使制造周期和成本显著降低。

本文引用格式

吴海贺 , 魏宝刚 , 王永祥 , 包呼日查 , 马秉贤 , 齐岩松 , 徐永胜 . 膝关节骨性关节炎步态分析特征及3D矫形鞋垫设计应用[J]. 科技导报, 2021 , 39(22) : 49 -56 . DOI: 10.3981/j.issn.1000-7857.2021.22.006

Abstract

The lower limb gait analysis is an effective method to quantitatively analyze the biomechanical changes of the internal motion of the knee joint, as well as an effective way to study the occurrence, the development and the intervention of the knee osteoarthritis (KOA). Two kinds of gait analysis experimental systems and their principles are reviewed, as well as the changes of the KOA patients' 3D lower limb gait. Due to the complexity of the lower limb biomechanics and the limitations of the research technology, the technique of the 3D orthopedic insoles is still in the preliminary stage, and there is no consensus with respect to the therapeutic effect of the products, and they have not been mass-produced and used. Therefore, the application principle and the manufacture process of the 3D orthopaedic insoles in the KOA are emphatically discussed. The dynamic and static structures and the changes around the knee joint of patients with the KOA, as being widely used in the design and the production of the 3D orthopaedic insoles, provide an important solution for the early conservative treatment of the KOA. And it can not only meet the dual requirements of comfort and functionality for patients, but also significantly reduce the manufacturing cycle and cost.

参考文献

[1] Ung A, Ssn B, Mh C, et al. Management of early and late presenting tibial stress fracture with advanced osteoarthritis of the knee:A dilemma among arthroplasty surgeons in developing countries[J]. The Knee, 2021, 29:95-100.
[2] 邢丹, 徐俊杰, 黄文汉. 步态图评估膝关节运动功能的专家共识(2020年版)[J]. 中华关节外科杂志(电子版), 2020, 14(6):651-656.
[3] Andriacchi T P, Mündermann A. The role of ambulatory mechanics in the initiation and progression of knee osteoarthritis[J]. Current Opinion in Rheumatology, 2006, 18:514-518.
[4] Mills K, Hunt M A, Ferber R. Biomechanical deviations during level walking associated with knee osteoarthritis:A systematic review and meta-analysis[J]. Arthritis Care and Research, 2013, 65(10):1643-1665.
[5] 韩亚丽, 王兴松. 人体行走下肢生物力学研究[J]. 中国科学技术科学, 2011, 41(5):592-601.
[6] Felson D T, Parkes M, Carter S, et al. The efficacy of a lateral wedge insole for painful medial knee osteoarthritis after prescreening:A randomized clinical trial[J]. Arthritis & Rheumatology, 2019, 71:908-915.
[7] Eea B, Mas C, Aaj D, et al. Gait initiation and lateral wedge insole for individuals with early knee osteoarthritist[J]. Clinical Biomechanics, 2020(80):105163.
[8] Ulbricht H, Hou M, Wang X, et al. The effect of correction algorithms on knee kinematics and kinetics during gait of patients with knee osteoarthritis[J]. Applied Bionics and Biomechanics, 2020(6):1-8.
[9] Ismailidis P, Nüesch C, Kaufmann M, et al. Measuring gait kinematics in patients with severe hip osteoarthritis using wearable sensors[J]. Gait Posture, 2020, 81:49-55.
[10] Tadano S, Takeda R, Sasaki K, et al. Gait characterization for osteoarthritis patients using wearable gait sensors (H-Gait systems)[J]. Journal of Biomechanics, 2016, 49:684-690.
[11] Ismailidis P, Hegglin L, Egloff C, et al. Side to side kinematic gait differences within patients and spatiotemporal and kinematic gait differences between patients with severe knee osteoarthritis and controls measured with inertial sensors[J]. Gait Posture, 2021, 84:24-30.
[12] Ismailidis P, Egloff C, Hegglin L, et al. Kinematic changes in patients with severe knee osteoarthritis are a result of reduced walking speed rather than disease severity[J]. Gait Posture, 2020, 79:256-261.
[13] Rahman J, Tang Q, Monda M, et al. Gait assessment as a functional outcome measure in total knee arthroplasty:A cross-sectional study[J]. BMC Musculoskeletal Disorders, 2015, 16(1):1-9.
[14] Chen F, Cui X, Zhao Z, et al. Gait Acquisition and analysis system for osteoarthritis based on hybrid prediction model[J]. Computerized Medical Imaging and Graphics, 2020, 85:101782.
[15] Fu H Y. Gait comparison between normal young people and knee osteoarthritis patients[J]. Journal of Clinical Rehabilitative Tissue Engineering Research, 2011(22):4115-4118.
[16] Mündermann A, Dyrby C O, Andriacchi T P. Secondary gait changes in patients with medial compartment knee osteoarthritis:Increased load at the ankle, knee, and hip during walking[J]. Arthritis & Rheumatism, 2005(9):2835-2844.
[17] 程晏, 王予彬. 膝关节骨性关节炎步态分析的研究进展[J]. 中国康复医学杂志, 2013, 28(7):676-680.
[18] Farrokhi S, Meholic B, Chuang W N, et al. Altered frontal and transverse plane tibiofemoral kinematics and patellofemoral malalignments during downhill gait in patients with mixed knee osteoarthritis[J]. Journal of Biomechanics, 2015, 48(10):1707-1712.
[19] Landry S C, Mckean K A, Hubley-Kozey C L, et al. Knee biomechanics of moderate OA patients measured during gait at a self-selected and fast walking speed[J]. Journal of Biomechanics, 2007, 40(8):1754-1761.
[20] Miyazaki T. Dynamic load at baseline can predict radiographic disease progression in medial compartment knee osteoarthritis[J]. Annals of the Rheumatic Diseases, 2002, 61(7):617-622.
[21] Foroughi N, Smith R, Vanwanseele B. The association of external knee adduction moment with biomechanical variables in osteoarthritis:A systematic review[J]. Knee, 2009, 16(5):303-309.
[22] Felson D T, Niu J, Gross K D, et al. Valgus malalignment is a risk factor for lateral knee osteoarthritis incidence and progression:Findings from the Multicenter Osteoarthritis Study and the Osteoarthritis Initiative[J]. Arthritis & Rheumatology, 2013, 65(2):355-362.
[23] Creaby M W, Wang Y, Bennell K L, et al. Dynamic knee loading is related to cartilage defects and tibial plateau bone area in medial knee osteoarthritis[J]. Osteoarthritis Cartilage, 2010, 18(11):1380-1385.
[24] Simic M, Hunt M A, Bennell K L, et al. Trunk lean gait modification and knee joint load in people with medial knee osteoarthritis:The effect of varying trunk lean angles[J]. Arthritis Care & Research, 2012, 64(10):1545-1553.
[25] Padua D A, Bell D R, Clark M A. Neuromuscular characteristics of individuals displaying excessive medial knee Displacement[J]. Journal of Athletic Training, 2012, 47(5):525-536.
[26] Gardner L I, Dziados J E, Jones B H, et al. Prevention of lower extremity stress fractures:A controlled trial of a shock absorbent insole[J]. American Journal of Public Health, 1988, 78(12), 1563-1567.
[27] Reeves N D, Bowling F L. Conservative biomechanical strategies for knee osteoarthritis[J]. Nature Reviews Rheumatology, 2011, 7(2):113-122.
[28] Hatef M R, Mirfeizi Z, Sahebari M, et al. Superiority of laterally elevated wedged insoles to neutrally wedged insoles in medial knee osteoarthritis symptom relief[J]. International Journal of Rheumatic Diseases, 2014, 17(1):84-88.
[29] Ishii Y, Deie M, Fujita N, et al. Effects of lateral wedge insole application on medial compartment knee osteoarthritis severity evaluated by ultrasound[J]. Knee, 2017, 24:1408-1413.
[30] Lack S, Barton C, Woledge R, et al. The immediate effects of foot orthoses on hip and knee kinematics and muscle activity during a functional step-up task in individuals with patellofemoral pain[J]. Clinical Biomechanics, 2014, 29(9):1056-1062.
[31] Hinman R S, Bowles K A, Metcalf B B, et al. Lateral wedge insoles for medial knee osteoarthritis:Effects on lower limb frontal plane biomechanics[J]. Clinical Biomechanics, 2012, 27(1):27-33.
[32] Allan R, Woodburn J, Telfer S, et al. Knee joint kinetics in response to multiple three-dimensional printed, customised foot orthoses for the treatment of medial compartment knee osteoarthritis[J]. Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine, 2017, 231(6):487.
[33] Kerrigan D C, Lelas J L, Goggins J, et al. Effectiveness of a lateral-wedge insole on knee varus torque in patients with knee osteoarthritis[J]. Archives of Physical Medicine and Rehabilitation, 2002, 83:889-893.
[34] Hinman R S, Bowles K A, Payne C, et al. Effect of length on laterally-wedged insoles in knee osteoarthritis[J]. Arthritis Care & Research, 2010, 59(1):144-147.
[35] Hsu W C, Jhong Y C, Chen H L, et al. Immediate and long-term efficacy of laterally-wedged insoles on persons with bilateral medial knee osteoarthritis during walking[J]. Biomedical Engineering Online, 2015(14):43.
[36] 曹萍, 吴小高. 3D打印技术在矫形鞋垫中的应用进展[J]. 中国康复理论与实践, 2015, 21(7):753-756.
[37] Pardoel S, Shalin G, Nantel J, et al. Early detection of freezing of gait during walking using inertial measurement unit and plantar pressure distribution data[J]. Sensors (Basel), 2021, 21(6):2246.
[38] Raaij T, Reijman M, Brouwer R, et al. Medial knee osteoarthritis treated by insoles or braces:A randomized trial[J]. Clinical Orthopaedics and Related Research, 2010, 468(7):1926-1932.
[39] Duffell L D, Jordan S J, Cobb J P, et al. Gait adaptations with aging in healthy participants and people with knee-joint osteoarthritis[J]. Gait & Posture, 2017, 57:246-251.
[40] Skou S T, Hojgaard L, Simonsen O H. Customized foot insoles have a positive effect on pain, function, and quality of life in patients with medial knee osteoarthritis[J]. Journal of the American Podiatric Medical Association, 2013, 103(1):50-55.
文章导航

/